The advantage at a glance
Application
Vortex meters are the most reliable & accurate measurement innovation technology available & widely accepted across the industries.
Theory of vortex type flow meters according to “Karman vortex”(click here) working theory designed for gas flow, steam or liquid’s volume flow, standard volume flow or mass flow measurement.
VFM60MV Series Multivariable Vortex Flowmeters incorporate Comate start-of-art technologies. This type multi-variable vortex mass flow metermake highly accurate measurements of various fluids including liquid, gas, saturated steam, and superheated steam. Support high temperature up to 350°C(662°F) in particular.
By helps of three built-in sensor, a vortex shedding flow velocity, a pressure transmitter and a temperature sensor, VFM60MV can more accurately measure the mass/standard flow rate of medium though density compensation.
VFM60MV Multivariable Digital Vortex Type Flowmeters:
Extremely high sensitivity, minimum flow rate down to 2m/s with 1:35 super wide turndown ratio
Patent dual-sensor design and optimized signal processing technology to ensure best anti-vibration
No moving parts, very small pressure loss
One vortex flowmeters can measure mass flow, temperature, pressure and density
Standard output is pulse and 4~20 mA, Hart@4~20mA and RS485 is available
Password protecting function and self-diagnose function

VFM60MV high temperature(350°C/662°F) version

Bluetooth software support
This function enables users who have COMATE flow meter in site to reach and configure the parameters more easily rather than lose the case and check the manual on how to set it. Most important is COMATE R&D team will help you to do this job just get the device online and click online diagnosis, our team-member will collect the data and help you to check where the problems may come from!

•Bluetooth app on a cellphone to connect Comate flowmeters
•Home interface can review real-time readings on the meter screen
•Setting interface help to do function setting & parameter setting
Support
•select output to pulse/4~20mA/frequency,
•select 4~20mA output parameters
•select unit of time/temperature/pressure/flow rate,etc
•input range of 4~20mA/pressure/temperature, etc
•Remote diagnosis function

| Fliud to measure | Liquid, steam, gas | |||
| Nominal diameter | Wafer/Flanged(ANSI/DN/DIN/JIS):15mm~300mm(1/2″~12″) | |||
| Insertion:300mm~700mm(12″~28″) | ||||
| Measurement range(m/s) | DN15~20 | DN25~32 | DN40~300 | |
| Steam | 6~70 m/s | 4~70 m/s | 2~70 m/s | |
| Gas | 6~60 m/s | 4~60 m/s | 2~60 m/s | |
| Liquid | 0.3~7m/s | 0.3~7m/s | 0.3~7m/s | |
| Accuracy | ±1% RD (insertion is 1.5%RD) | |||
| For multi-variable version: temperature ±1°C,pressure:0.75% FS | ||||
| Repeatability | 0.3% RD | |||
| Output | Pulse / 4~20mA / 4-20mA@ HART / RS-485 | |||
| Process Temperature Range | -40℃~150℃ ; -40℃~250℃ ; -40℃~350℃ ; | |||
| Process Pressure Limit | –0.1 MPa (–1 kg/cm2) to flange rating | |||
| Ambient Temperature Range | –40 to 85°C | |||
| Ambient Humidity | 5 to 100% RH | |||
| Electrical Connection | 1/2 NPT, M20 × 1.5 | |||
| Materials | 304 SS, 316 SS, 316L SS | |||
The Nm3/hr unit of flow range, is the standard flow under 20dgr C and 0.1Mpa, vortex flow meter range should be base on actual velocity range, than transfer to standard flow or mass flow according to the pressure and temperature in the pipe.