This application is specially designed for air and N2 and other non-corrosive applications in the small pipe
from 1/4″ to 1″
1) Thermal mass measuring technology, direct mass/standard flow measurement
2) Temperature measurement as an option
3) 6 digit dual-line LED screen
4) Low-cost economical model.
5) Blue tooth for operating on cellphone
6) 1.5% reading + 0.3% full scale accuracy in 100:1 measurement range
7) 1/4″~1″ (8mm~25mm) small pipeline measurement, G thread connection optional
8) On-line diagnose available
| Media Compatibility | Air, Nitrogen and other non-corrosive fluid |
| Pipe diameter | 8mm~25mm (1/4″~1″) |
| Flow velocity range | 0.3~30Nm/s or 0.6~60Nm/s or 0.9~90Nm/s |
| Accuracy | 1.5% of reading+ 0.3% of full scale |
| Repeatability | 0.3% of reading |
| Storage Temperature | -20~+50°c |
| Transportation Temperature | -30~60°c |
| Temperature of medium | -20~100°c |
| Pressure of medium | 1.6 Mpa |
| Power supply | 10~35 VDC / 200 mA |
| Response time | 160 millisecond |
| Output Frequency , | 4~20mA |
| Communication | RS~485, Bluetooth |
| Date displayed | Mass flow, Volume flow in normal or standard condition |
| Total flow , Temperature, and Velocity | |
| Housing material | Aluminum alloy |
| Wet part material | Aluminum alloy (304SS and 316SS optional) |
| Ingress protection grade | IP54 |